Medicine Platform
搜索
Product Catagories
首页 > Biomedical Research > C4-Deficient Guinea Pig Serum
C4-Deficient Guinea Pig Serum
单价 $478.89对比
询价 暂无
发货
品牌 CompTech
过期 长期有效
更新 2025-08-12 14:27
 
详细信息
存储温度: -70oC or below. Minimize freeze/thaw cycles.

来源:Guinea pigs genetically deficient in C4

存储溶液:None added

参考文献:Dodds, A.W. and Sim, R.B. editors (1997) Complement. A Practical Approach (ISBN 019963539) Oxford University Press, Oxford. Ellman, L., Green, I. and Frank, M.M. (1970) Genetically controlled total deficiency of the fourth component of complement in the guinea pig. Science 170:74-75. Ellman, L., Green, I., Judge, F. and Frank, M.M. (1971) In vivo studies in C4-deficient guinea pigs. J. Exp. Med. 134:162-175. Frank, M.M., May, J., Gaither, T. and Ellman, L. (1971) In vitro studies of complement function in sera of C4-deficient guinea pigs. J. Exp. Med. 134:176-187. Morgan, B.P. ed. (2000) Complement Methods and Protocols. (ISBN 0-89603-654-5) Humana Press, Inc., Totowa, New Jersey. Wagner, E., Platt, J.L., Howell, D.N., Marsh, H.C. Jr and Frank, M.M. (1999) IgG and complement-mediated tissue damage in the absence of C2: evidence of a functionally active C2-bypass pathway in a guinea pig model. J. Immunol. 163:3549-3558.

官网链接:http://www.complementtech.com/product-description/Dpl-Sera/C4-D%20Guinea%20Pig.htm

商品关键词:C4-Deficient Guinea Pig Serum,A305,CompTech

简单描述:C4-deficient guinea pigs were characterized in 1971 as being completely genetically and functionally deficient in C4 (Ellman, L. et al. (1970); Ellman, L. et al. (1971); Frank, M.M., et al. (1971)). This line of guinea pigs has been maintained and used extensively for the characterization of complement. In fact, these animals were a key element in the rediscovery and detailed characterization of the alternative pathway of complement (Ellman, L. et al. (1971); Frank, M.M., et al. (1971)). The product is tested for the absence of C4 by functional assays for classical pathway activity. C4-D guinea pig serum reconstituted with human C4 is certified to possess a functional classical pathway for complement activation after reconstitution (Morgan, B.P. (2000); Dodds, A.W. and Sim, R.B. (1997)). The absence of C4 would also be predicted to prevent complement activation by the lectin pathway, but the function of this pathway is not tested.

Concentration: >30 mg protein/mL (see Certificate of Analysis for actual conc.)

Form: Frozen liquid

Activity: >1,000,000 C4H50 units/mg C4 added to assay with C4-D GPS

Purity: No C4 detectable by hemolytic assay

Preservative: None, 0.22 µm filtered

Physical Characteristics : C4-D guinea pig serum is supplied as a clear, straw-colored liquid containing all proteins of normal guinea pig serum except complement component C4.

Function: The depleted serum is tested for remaining classical pathway activity by hemolytic assays using antibody-sensitized sheep erythrocytes (CompTech #B200). The depleted serum is reconstituted with human C4 (CompTech #A105) and retested to verify that a functional classical and alternative pathways are restored. The Certificate of Analysis provided with each lot gives a description of the assays and specific titers for the depleted and reconstituted sera compared to normal human serum.

Assays: The unit of classical pathway activity is the CH50. A similar unit, the C4H50, is used to quantitate the activity of C4 and C4-D guinea pig serum. A C4H50 unit is the amount of functional C4 needed to lyse 50% of 3 x 107 EA cells (antibody-sensitized sheep erythrocytes (CompTech #B200)) when that amount of C4 (CompTech #A105) is incubated with the recommended volume of C4-D guinea pig serum in GVB++ (CompTech #B100) in a total volume of 500 µL for 30 min at 37oC. This amount of C4 indicates the sensitivity of the assay for C4 which is typically less than 2 ng C4 with 10 µL C4-D guinea pig serum. See the Certificate of Analysis for lot specific values.

Precautions/Toxicity/Hazards: The source is human serum, therefore precautions appropriate for handling any blood-derived product must be used even though the source was shown by certified tests to be negative for HBsAg and for antibodies to HCV, HIV-1 and HIV-II.

Hazard Code: B WGK Germany 3MSDS is available upon request.


官网链接: www.annoron.com
办公电话: 010-56256916
官方售后: 400-965-8633
企业QQ: 3198592576、3212874516