2 Sample Test Kit, if tested in 2 strains (TA98, TA100), triplicates, 6 doses, +/- S9, negative, positive controls, sterility control. PB/NF induced Rat liver S9 and controls (4-NQO, 2-NF, 2-AA) are included in the kit. S9 cofactor solution and microplates are not included in the kit.
Description
MicroAmes6 is a ready to use, miniaturized kit for the Ames test including strains, media, PB/NF induced rat liver S9, positive controls, ampicillin, booster solution. All components are quality controlled and come with a certificate of analysis.
Test Principle of the Ames Test
Bacteria are exposed to different concentrations of a test sample (11 mg / strain), as well as a positive and a negative control in a medium containing limited quantities of histidine (S. typhimurium) to support approximately two cell divisions. The cultures in each condition (negative control, test samples and positive controls) are poured in 6 well plates. The cells are exposed to the compound in absence and presence of S9. Rat liver post mitochondrial S9 fraction mimics the effect of the chemical after metabolization. Within three days, cells that have undergone a genetic reversion event to amino acid prototrophy will grow and form colonies. The revertant counts will be compared to those grown in the solvent (negative) control wells. A dose-dependent and significant increase in the number of revertant colonies upon exposure to test sample relative to the solvent controls indicates that the sample is mutagenic. A sterility plate for S9 and buffer is used a contamination control.
Service analytics for early drug discovery with test compound of 11 mg / strain (+/- S9) with the MicroAmes6 assay system is available as well under GLP and non GLP conditions, please contact info@xenometrix.ch.
Characteristics for Ames Test Kit in 6Well Agar Plates
- Quality controlled products: all products included in the kit are quality controlled according to OECD TG471
- Certificate of Analysis: Provided with each kit
- Enough Material to process Strains individually, +/- S9
- Shipped at Room Temperature from external Storage in Germany or from Switzerland
- 4 times less test compound as compared to the Ames Test in Petri Dishes
- Less hands-on-time and simultaneous processing of several replicates
- 3Rs - significant less consumption of rat liver liver S9, thus less test animals
- Waste - Significant less plastic waste and thus reduced contaminated waste in environment
- Analytical services available, please contact info@xenometrix.ch