存储温度: -70oC or below. Minimize freeze/thaw cycles.
来源:Normal human serum (shown by certified tests to be negativefor HBsAg and for antibodies to HCV, HIV-1 and HIV-II).
存储溶液:10 mM sodium phosphate, 145 mM NaCl, pH 7.3
参考文献:Dodds, A.W. and Sim, R.B. editors (1997) Complement. A Practical Approach (ISBN 019963539) Oxford University Press, Oxford. Law, S.K.A. and Reid, K.B.M. (1995) Complement 2nd Edition (ISBN 0199633568) Oxford University Press, Oxford. Morgan, B.P. ed. (2000) Complement Methods and Protocols. (ISBN 0-89603-654-5) Humana Press, Inc., Totowa, New Jersey.
官网链接:http://www.complementtech.com/product-description/Dpl-Sera/C5-Dpl.htm
商品关键词:C5-Dpl,A320,CompTech
简单描述:Normal human serum depleted of complement C5 protein by immunoaffinity chromatography. The product is tested for the absence of C5 by functional assays for classical pathway activity and alternative pathway activity and for C5 protein by double immunodiffusion. C5-Dpl is certified to possess functional classical and alternative pathways for complement activation up to the step of C5 activation (Law, S.K.A. and Reid, K.B.M. (1995); Morgan, B.P. ed. (2000); Dodds, A.W. and Sim, R.B. editors (1997)). Functional complement systems can be reconstituted by addition of purified C5 protein (75 µg/mL) indicating that all other complement components necessary for complement activation are present.
Concentration: >50 mg protein/mL (see Certificate of Analysis for actual conc.)
Form: Frozen liquid
Activity: >80% versus normal human serum standard
Purity: No C5 detectable by immunodiffusion
Preservative: None, 0.22 µm filtered
Physical Characteristics : Clear, straw-colored liquid containing all proteins of normal human serum except complement component C5.
Function: The depleted serum is tested for remaining classical pathway hemolytic activity using antibody-sensitized sheep erythrocytes (CompTech #B200) and for alternative pathway function using rabbit erythrocytes (CompTech #B300). The depleted serum is reconstituted with 75 µg/mL C5 (CompTech #A120) and retested to verify that a hemolytic function is restored. The Certificate of Analysis provided with each lot gives a description of the assays and specific titers for the depleted and reconstituted sera compared to normal human serum.
Assays: The unit of classical pathway activity is the CH50. A similar unit, the C5H50, is used to quantitate the activity of C5 and C5-Dpl. A C5H50 unit is the amount of C5 needed to lyse 50% of 3 x 107 EA cells (antibody- sensitized sheep erythrocytes (CompTech #B200)) when that amount of C5 (CompTech #A120) is incubated with the recommended volume of C5-Dpl in GVB++ in a total volume of 500 µL for 30 min at 37oC. This amount of C5 indicates the sensitivity of the assay for C5 which is typically about <5 ng C5 with 25 µL C5-Dpl. See the Certificate of Analysis for lot specific values. Controls without C5 exhibit typically <5 % lysis. After full reconstitution (75 µg C5/mL C5-Dpl) lysis should be 100% in this assay.
Precautions/Toxicity/Hazards: The source is human serum, therefore precautions appropriate for handling any blood-derived product must be used even though the source was shown by certified tests to be negative for HBsAg and for antibodies to HCV, HIV-1 and HIV-II.
Hazard Code: B WGK Germany 3MSDS is available upon request.
官网链接: www.annoron.com
办公电话: 010-56256916
官方售后: 400-965-8633
企业QQ: 3198592576、3212874516